What does each stage of air-to-water filtration do?
Each filtration stage in an air-to-water machine removes a different group of substances, using the same treatment types found in household and small-scale water systems.
Sediment filters remove suspended particles such as sand, silt and clay by passing water through a material rated by the smallest particle it traps. A sediment prefilter is commonly fitted before a reverse osmosis membrane because hard water and particles can foul (clog) the membrane.
Reverse osmosis forces water at high pressure through semi-permeable membranes that physically remove contaminants, rejecting part of the incoming water as a concentrated stream. It reduces most dissolved and suspended inorganic impurities, though it is not typically recommended for removing organic impurities, including bacteria.
Carbon filters use granular activated carbon to remove taste- and odour-producing compounds, natural organic matter and volatile organic compounds, adsorbing (binding) impurities to the carbon as water flows through. This stage matters for water from air because condensate is not sterile and compounds from the air can end up in it.
Sterilisation with UV uses light from UV lamps or LEDs to inactivate microbes and requires a reliable supply of electricity. The delivered UV dose depends on intensity and exposure time. Cloudy water limits UV penetration, so UV is typically the last device in a treatment system, and lamps weaken over time and must be changed to the manufacturer's recommendations.
Why do air-to-water filtration stages run in a set order?
Air-to-water filtration stages run from coarse to fine so particles come out first, protecting later stages and leaving clear water for disinfection. Under the Australian Drinking Water Guidelines, the effect of turbidity on disinfection is one of three aspects of turbidity to manage, and low turbidity is desirable at the time of disinfection. The guidelines also rely on multiple barriers, because no single barrier works against every contaminant or works all the time. Reverse osmosis and sterilisation each cover gaps left by the other.
Why do air-to-water filters need replacing on schedule?
Water treatment parts clog or wear out with use, and an unmaintained system may make water quality worse. Every water treatment system needs ongoing maintenance, with filters replaced to the manufacturer's recommended schedule. Each stage has wear items: sediment cartridges need periodic replacement, reverse osmosis membranes and other system parts wear out over time, carbon filters must be changed on the manufacturer's recommendation, and UV lamps need changing as they weaken.
Which filtration stages do Sky Drop machines use?
Sky Drop machines include sediment, reverse osmosis and carbon stages, followed by sterilisation. Scheduled filter replacement is part of the servicing included with rental, so you do not need to track it yourself. Sky Drop is having its machines tested against the Australian Drinking Water Guidelines and will publish the results.
For more detail, see whether water from air is safe to drink, how the machines work and our water quality page. To talk through a site, call 1300 232 004 or contact us for a free site consultation.