How does dew point affect an atmospheric water generator?
An atmospheric water generator can only pull water from the air once it cools that air below its dew point, which is the temperature to which air must be cooled to produce condensation. Air always holds some water as an invisible vapour, and the higher the dew point, the more moisture the air contains.
When moisture-laden air touches a surface colder than its dew point, that vapour turns into liquid on the surface. The gap between the air temperature and the dew point sets how much cooling, and therefore how much energy, the machine needs to collect water.
What is the difference between relative humidity and absolute humidity?
Relative humidity is the percentage of moisture the air could hold at its current temperature, while absolute humidity is the actual amount of water vapour in the air. Formally, relative humidity is the ratio of vapour pressure to saturation vapour pressure, showing how close the air is to saturation, whereas dew point reflects the actual quantity of moisture present.
Those two measures can differ a lot because warm air holds more moisture than cool air. A reading of 60% relative humidity on a hot day means more water in each cubic metre of air than 60% on a cold morning, so temperature and humidity have to be read together.
How does an atmospheric water generator condense water?
Most atmospheric water generators use a vapour-compression refrigeration cycle, a condenser and a cooling coil to pull moisture from the air in the same way a household dehumidifier does. The refrigeration cycle keeps the coil cold while a fan moves air across it, so water droplets form on the coil, run off and drip into a collection tray.
Output depends on airflow, heat exchanger effectiveness, cooling capacity, and the temperature and humidity of the inlet air. Commercial machines commonly include inlet air filters, fans, a food-grade coating over the cooling coil and water treatment units.
How does an atmospheric water generator treat condensed water?
An atmospheric water generator filters and treats collected water before storing it, because atmospheric condensate is not sterile and should be treated adequately before drinking. Volatile organic compounds in air can also dissolve in the condensate and feed microbial growth in plumbing and stored water.
For that reason, refrigeration-based generators are typically fitted with an air filter and water treatment stages after collection. Treatment stages vary by model before the water goes to a storage tank, and the tank and its plumbing need regular maintenance. Our guides on air-to-water filtration and whether water from air is safe to drink cover those stages in more detail.
What do Sky Drop atmospheric water generators need to run on site?
Sky Drop machines need electricity from the mains, a generator or solar, and air between 15 and 40°C with at least 35% humidity. Very dry air limits any refrigeration-based generator, which is typically deemed infeasible where average relative humidity is under 40%, and Sky Drop machines make less water in dry air.
Servicing is included with rental. You can see how the machines work in the field and view the range of machines. To talk through a site, call us on 1300 232 004 or contact us for a free site consultation.