How much water can you make from air?

The amount of water an air-to-water machine makes depends mainly on the humidity and temperature of the air it draws in. Warm, humid air gives the most, dry air gives much less, and a rated figure is measured at fixed conditions that a real site rarely holds all day.

What decides how much water comes out?

The US Environmental Protection Agency states that water production rates of atmospheric water generators are highly dependent on the air temperature and the amount of water vapour in the air. Most machines condense water with a cooled coil, so the question is how much vapour each cubic metre of air gives up before the machine runs out of cooling.

Thermopedia's overview lists airflow, heat exchanger effectiveness, cooling capacity, and the temperature and humidity of the inlet air as the main factors. Power matters too, because the compressor and fans set the cooling available. Sky Drop machines need power from the mains, a generator or solar. For the range, see our machines.

Why does dry air make less water?

The air has to be cooled to its dew point before water forms. Thermopedia explains that when the dew point is close to the air temperature, little cooling is needed and most of the energy goes into condensing water. In hot, dry air the dew point is far below the air temperature, so a lot of energy is spent cooling the air before any water forms.

The same source reports that active refrigeration is not feasible when the dew point falls below 2 degrees C, because of frost on the coil. A PLOS Water study adds that refrigeration-based machines are typically deemed infeasible in places averaging under 40% relative humidity. Sky Drop machines make less water in dry air, and they need at least 35% humidity and 15 to 40 degrees C to work.

Why are rated figures measured at set conditions?

Rated figures are given at one fixed temperature and humidity so that models can be compared. Dehumidifiers show how much that choice matters. ENERGY STAR explains that a dehumidifier's capacity is the water removed per day at test conditions. When the US Department of Energy changed the test temperature from 80 to 65 degrees F, the same kind of machine got a lower capacity rating, because there is less water to remove in cooler air.

Air-to-water machines work the same way. A figure measured in warm, humid test conditions describes output in those conditions only.

Why is real output usually lower?

Real air is not held at test conditions. The Bureau of Meteorology notes that relative humidity changes with temperature, so it falls and rises across a day. The Bureau also publishes average 9 am and 3 pm relative humidity maps by month, which show how much humidity differs between regions and seasons across Australia.

The PLOS Water study modelled commercial machines against 35 years of United States weather data. It concluded that they are not suited to be stand-alone water sources for much of the year across the country, with warm, humid places such as Hawaii the exception. Output varied by season and by location. A machine rated in warm, humid conditions will produce less at a site that is drier or cooler than the rating.

When you size a supply, use the humidity and temperature range at your site across the year, not a single rated figure. Our water supply for remote sites page covers planning, and the guide on how air-to-water machines work explains the physics. If you want a site checked against your daily water needs, contact us for a free site consultation.

Related reading

Questions

Why does an air-to-water machine make less water in dry air?

Dry air holds less water vapour, so the air has to be cooled much further before water condenses, and each cubic metre of air yields less water. Sky Drop machines make less water in dry air and need at least 35% humidity.

Is the rated output what I will get on site?

Usually not all day. A rated figure is measured at one set temperature and humidity, and real conditions change through the day and the year, so real output is usually lower.

What conditions do Sky Drop machines work in?

Sky Drop machines work in 15 to 40 degrees C and at least 35% humidity. See the machines page for the range.

Does output change between day and night?

It can. Relative humidity rises as air cools, so conditions at night or early morning can differ a lot from the afternoon.

How much water can an atmospheric water generator produce?

It depends on the model and on the humidity and temperature of the air. Rated output is measured at set conditions and real output is usually lower, so we estimate output for your site at the consultation.

How much water can you get from the air?

The air only gives up as much as it holds, so warm, humid air gives the most and dry air gives little. Every Sky Drop machine needs at least 35% humidity.