What is dew point?
Dew point is the temperature to which air must be cooled to produce condensation. It reflects how much moisture is in the air and is always the same as or lower than the air temperature. To calculate dew point, you need the air temperature and relative humidity. For what relative humidity measures, see does 50% humidity mean the air is 50% water.
What is the formula for dew point?
You calculate dew point accurately with a Magnus-type formula for saturation vapour pressure using the coefficients A = 17.625 and B = 243.04 degrees C. Those coefficients give saturation vapour pressure within 0.4% from -40 to 50 degrees C. Solving for dew point gives, in plain text:
- g = ln(RH / 100) + (17.625 x T) / (243.04 + T)
- dew point = 243.04 x g / (17.625 - g)
Here, T is air temperature in degrees C, RH is relative humidity in per cent, and ln is the natural logarithm.
How do you calculate dew point for 30 degrees C and 50% humidity?
Air at 30 degrees C and 50% relative humidity has a dew point of about 18.4 degrees C using the Magnus-type formula:
- (17.625 x 30) / (243.04 + 30) = 528.75 / 273.04 = 1.9365
- ln(50 / 100) = ln(0.5) = -0.6931
- g = 1.9365 - 0.6931 = 1.2434
- dew point = 243.04 x 1.2434 / (17.625 - 1.2434) = 302.20 / 16.3816 = 18.4 degrees C
A surface cooler than 18.4 degrees C will collect condensation from this air. At 35% relative humidity and 30 degrees C, the same steps give about 12.9 degrees C, so drier air has to be cooled further.
Is there a simpler way to estimate dew point?
Yes, in moist air above 50% relative humidity, the dew point falls about 1 degree C from the air temperature for every 5% drop in relative humidity below 100%. Written out, the rule of thumb is dew point = T - (100 - RH) / 5. At 30 degrees C and 70% humidity, that gives 30 - 6 = 24 degrees C, which closely matches 23.9 degrees C from the full formula. At 30 degrees C and 50% humidity, the shortcut gives 20 degrees C against 18.4 degrees C from the full formula, so use the full formula in drier air.
At what temperature does water vapour start to condense?
Water vapour starts to condense at the dew point, which is why water forms on a cool bathroom mirror when the mirror is below that temperature. Air-to-water machines use the same effect with a cold coil. The dew point also sets how hard a machine works, because more cooling is needed when it sits far below the air temperature. Sky Drop machines need at least 35% humidity and air between 15 and 40 degrees C; see how it works. For how this affects output, see how much water you can make from air and how atmospheric water generators work.
To have your site's conditions assessed, call 1300 232 004 or contact us for a free site consultation.